6 mm flush,Usable up to SIL 2 acc. to IEC 61508
Switching function : Normally closed (NC) Output type : NAMUR Rated operating distance : 6 mm Installation : flush Assured operating distance : 0 ... 4.86 mm Reduction factor rAl : 0.4 Reduction factor rCu : 0.3 Reduction factor r304 : 0.85 Output type : 2-wire Nominal voltage : 8.2 V (Ri approx. 1 kΩ) Switching frequency : 0 ... 2000 Hz Hysteresis : typ. % Current consumption : Safety Integrity Level (SIL) : SIL 2 MTTFd : 4566 a Mission Time (TM) : 20 a Diagnostic Coverage (DC) : 0 % Standard conformity : IECEx approval : ATEX approval : UL approval : cULus Listed, General Purpose CCC approval : NEPSI approval : TIIS approval : on request ANZEx : 18.3018X KCC approval : Ambient temperature : -25 ... 100 °C (-13 ... 212 °F) Connection type : cable Housing material : Stainless steel 1.4305 / AISI 303 Sensing face : PBT Degree of protection : IP68 Cable : Use in the hazardous area : see instruction manuals