40 mm non-flush,Usable up to SIL 3 acc. to IEC 61508

Switching function : Normally closed (NC)
Output type : NAMUR with safety function
Rated operating distance : 40 mm
Installation : non-flush
Assured operating distance : 0 ... 32.4 mm
Reduction factor rAl : 0.4
Reduction factor rCu : 0.3
Reduction factor r304 : 0.85
Safety Integrity Level (SIL) : up to SIL3 acc. to IEC 61508 Danger! In safety-related applications the sensor must be operated with a qualified fail safe interface from Pepperl+Fuchs, such as KFD2-SH-EX1.
Consider the exida Functional Safety Assessment document which is available on www.pepperl-fuchs.com as an integral part of this product's documentation.
Output type : 2-wire
Nominal voltage : 8.2 V (Ri approx. 1 kΩ)
Switching frequency : 0 ... 100 Hz
Current consumption :
Safety Integrity Level (SIL) : SIL 3
MTTFd : 7560 a
Mission Time (TM) : 20 a
Diagnostic Coverage (DC) : 0 %
Standard conformity :
IECEx approval :
ATEX approval :
EAC conformity : TR CU 012/2011
UL approval : cULus Listed, General Purpose
CCC approval :
NEPSI approval :
KCC approval :
Ambient temperature : -40 ... 100 °C (-40 ... 212 °F)
Connection type : screw terminals
Core cross section : up to 2.5 mm2 , stripped insulation length: 7 mm
Connection (system side) : screw terminals , M20 x 1.5 cable gland , usable thread length 10 mm , screw-in depth max. 10 mm
Housing material : PBT
Sensing face : PBT
Degree of protection : IP68
Use in the hazardous area : see instruction manuals