Comfort series,2 mm flush,Usable up to SIL 2 acc. to IEC 61508
Switching function : Normally closed (NC) Output type : NAMUR Rated operating distance : 2 mm Installation : flush Assured operating distance : 0 ... 1.62 mm Reduction factor rAl : 0.4 Reduction factor rCu : 0.3 Reduction factor r304 : 0.85 Output type : 2-wire Nominal voltage : 8.2 V (Ri approx. 1 kΩ) Switching frequency : 0 ... 2000 Hz Suitable for 2:1 technology : yes , Reverse polarity protection diode not required Current consumption : Safety Integrity Level (SIL) : SIL 2 MTTFd : 5887 a Mission Time (TM) : 20 a Diagnostic Coverage (DC) : 0 % Standard conformity : IECEx approval : ATEX approval : UL approval : cULus Listed, General Purpose CCC approval : NEPSI approval : ANZEx : 18.3018X KCC approval : Ambient temperature : -25 ... 100 °C (-13 ... 212 °F) Connection type : Connector plug Housing material : Stainless steel 1.4305 / AISI 303 Sensing face : PPS Degree of protection : IP67 Connector : Use in the hazardous area : see instruction manuals